GKO LONG SIDE SIZE 2 GALV
Art. No. 124521
- External dimensions WxHxD (mm)
- 50 x 201 x 100
- Weight (kg)
- 1.5
Roxtec rectangular frames · Roxtec
The Roxtec GKO is a bolted together metal frame with flange. The frame parts are assembled to create different sizes and combinations of openings. The frame extends from the structure so that it can be bolted over multiple or irregular apertures. It is suitable for installation around existing cables and pipes.
Pricing, availability, and lead time are confirmed on quote — send your quantities and application details and a human responds.
Select the closest article number, then include the opening, cable or pipe sizes, quantity, and required date in the request.
Art. No. 124521
Art. No. 124522
Art. No. 124523
Art. No. 124524
Art. No. 124525
Art. No. 124526
Art. No. 124527
Art. No. 124528
Art. No. 124529
Art. No. 121279
Art. No. 121284
Art. No. 121285
Art. No. 121286
Art. No. 121304
Art. No. 121313
Art. No. 121314
Art. No. 121315
Art. No. 121293
These links open current files hosted by Roxtec. Check the source document revision before use.
Certificate rows reproduce factual source fields. They do not confirm applicability to a specific assembly. Open the source record and ask AMFSS to check the application.
| Authority | Rating | Division / structure | Cable | Pipe | Type approval | Status |
|---|---|---|---|---|---|---|
| RISE | E fire EI fire | Brickwork Casted Concrete Concrete or Brickwork Gypsum Lightweight concrete Sandwich | Construction Other Telecom | ABS Copper PE Plastic PVC Steel | 0402-CPR-SC1479-11 (ETA-11/0313) | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Construction Telecom | Conduit Steel | C-AJ-8309 | No renewal status stated |
| Roxtec International AB | E fire EI fire | Brickwork Casted Concrete Concrete or Brickwork Gypsum Lightweight concrete Sandwich | Construction Telecom | ABS Copper PE Plastic PVC Steel | CE Declaration of Conformity (ETA-11/0313) | No renewal status stated |
| Roxtec International AB | E fire EI fire | Brickwork Casted Concrete Concrete or Brickwork Gypsum Lightweight concrete Sandwich | Construction Other Telecom | ABS Copper PE Plastic PVC Steel | CE Declaration of Performance (DoP) ETA 11/0313 | No renewal status stated |
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | — | MEDB00003M3 | No renewal status stated |
| DNV | A class fire Gas tightness (catastrophic) Water tightness (catastrophic) | Steel | Marine | — | MERB00003M3 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | — | Conduit Steel | W-J-1301 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Fiber Telecom | — | W-J-3245 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Fiber Telecom | — | W-J-3246 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | — | W-J-3247 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | — | W-J-3250 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | — | W-J-3252 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction | — | W-J-3254 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Construction Telecom | — | W-J-8076 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete Lightweight concrete | Armored Construction Telecom | Conduit Steel | W-J-8088 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Armored Construction Other | — | W-L-3359 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Armored Construction Other | — | W-L-3362 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Armored Construction Other | — | W-L-3364 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Armored Construction Other | — | W-L-3366 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Sandwich | Construction Fiber Telecom | Conduit Steel | W-N-8002 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete | Other Telecom | — | XHEZ.C-AJ-3160 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete | Armored Construction Fiber Other Shielded Telecom Unshielded | — | XHEZ.C-AJ-3388 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Concrete | Other Telecom | — | XHEZ.W-J-3052 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Fiber Other Telecom | — | XHEZ.W-L-3114 | No renewal status stated |
| Underwriters Laboratories Inc. | F fire T fire | Gypsum | Fiber Other Telecom | — | XHEZ.W-L-3115 | No renewal status stated |
Source checked 2026-08-08: official Roxtec product page.
Roxtec rectangular frames form the frame portion of modular cable and pipe transit systems. Frame type and components must be matched to the opening and application.
Typical applications:
Not sure this is the right product? Compare the Roxtec rectangular frames family or describe your application.